According to leading containment isolator manufacturers, it has been estimated that up to 50% of new pharmaceutical products are now being set by the pharmaceutical industry with Operator Exposure
|
|
Limits (OEL's) at =10µg/m3.
A leading European Pharmaceutical company needed to complete various clinical trials with batch sizes of highly dusty materials weighing between 1 - 20kg through a U5 Comil®.
The STEL (Short Term Exposure Limit) of the worst case APIs (Active Pharmaceutical Ingredients) that the customer is planning on milling is
|
|
 |
40µg/m3.
The U5 Comil® is housed within an isolator and the mill's spindle had to provide containment of API blends to 5µg/m3 when processing.
In testing developed by the customer and conducted by the isolator manufacturer, the U5 Comil® was subjected to a pressure of 150 Pa for one minute.
The maximum allowable pressure drop in the plastic simulation bag after one minute was 8 Pa.
The isolator company tested the U5 head as per the testing protocol and the U5 Comil® achieved a 1 Pa pressure drop over a one minute |
 |
interval, exceeding the requirements by a large margin.
Quadro® Comils® are designed to the strictest cGMP standards and have proven themselves over the years to provide maximum containment capabilities, making the Comil® the mill of choice for many isolator manufacturers and end users alike.